The technical field and correct installation steps of BILON brand aseptic homogenizer

Sterile homogenizer, also known as beating homogenizer, beating homogenizer. Mainly used for tissue dispersion in the field of biotechnology, sample preparation in the field of medicine, enzyme treatment in the food industry, and in the pharmaceutical industry, cosmetics industry, paint industry and petrochemical industry.

拍打式无菌均质器.jpg

The device is equipped with a fully open glass transparent window door, which is easy to clean, and the glass transparent window is easy to observe. Using large-screen LCD display, the working time and homogenization speed are intelligently adjustable, and the beater can also adjust the front and rear distance at will. It can effectively separate the sample surface and the contained microbial uniform sample. The sample is isolated and operated with a disposable sterile homogeneous filter bag to ensure hygiene and safety, no contact with the instrument, no sample leakage and no system cleaning. It has the characteristics of convenient and fast, accurate results, homogeneous and soft, no pollution, no damage, no heating, no sterilization treatment, no need to wash utensils, and good repeatability requirements. This product is also suitable for the homogenization of tumor tissues (such as intestinal cancer, gastric cancer, liver cancer, breast cancer), which can obtain a large number of single cells. If necessary, the tissue cells can be broken softly by extending the homogenization time.

The BILON brand sterile homogenizer makes the process of extracting bacteria from solid samples very simple, just add the sample and diluent to the sterile sample bag, and then put the sample bag into the flapping homogenizer The sample can be processed in the middle. Effectively separate the homogeneous samples of microorganisms contained inside and on the surface of the solid sample, ensuring that all the samples are mixed in the sterile bag. The processed sample solution can be directly sampled and analyzed without risk of sample change and cross-contamination. Application areas: microbiological analysis of food; homogenization of animal tissues, biological samples, cosmetics; fish, meat, vegetables, fruits, biscuits; microbiological analysis of drugs, etc.

When using the sterile homogenizer of Shanghai Bilang Instrument Manufacturing Co., Ltd., there are eight points to be noted. Treating these problems correctly can make the homogenizer better serve you.

1) The power plug must be firmly inserted into place. Looseness may affect the computer controller and cause a crash. If a crash occurs, turn off the power switch on the rear side, and restart after 3 minutes of shutdown.

2) Please do not open the homogenizer door at will when the hammer board is working to avoid overflow of sample liquid. It should be built according to "open / stop", and the equipment will automatically stop running. After closing the door, press "Open / Stop" to build, and the equipment will automatically complete the rest of the work. Do not reverse the operation.

3) If the instrument is not used for a long time, the power should be cut off and the plug removed. Prevent the aging of electronic components inside the sterile homogenizer.

4) The bottom of the homogenizer door is designed to prevent accidental rupture of the homogenization bag and facilitate the cleaning of spillage. The bottom is designed to be empty and can be used to place the water tray. It is best not to open the homogenizer door when the homogenizer is working, causing unnecessary losses.

5) Before running the machine, please check carefully whether there are foreign objects in the homogenization box, so as to avoid failure and damage to the homogenization bag during work.

6) Hard, sharp, hard and sharp materials, such as lumps, bones, and ice, should not be used to avoid damaging the homogeneous bag.

7) The storage of the instrument and the homogenous bag should avoid direct sunlight, especially the homogenous bag should be stored in a place without sunlight or ultraviolet radiation to avoid aging.

8) When the amount is small, the speed needs to be increased, and when the homogenous fiber is tough, you can use the rear knob to adjust the distance between the flapper and the window to achieve a better homogenization effect. Pay attention to the adjusted distance to avoid the occurrence of air strikes and other damage to the sterile homogenizer.

The correct steps for using a sterile homogenizer are:

1. Put the sample to be treated in a sterile homogeneous bag.

2. Open the homogenizer door (which can be fully opened) and clamp the opening of the sterile bag when closing the homogenizer door.

3. Set the use program (such as slap speed, slap time, etc.) to perform slap homogenization.

4. After the experiment, open the homogenizer door and take out the sample.

The use of a sterile homogenizer can greatly extend its service life and use effect if the above points are achieved.

Welcome to Baidu search Shanghai Bilang Mall to learn more about the details of the instrument!

The PLA Disposable Tableware is completely different from traditional plastic tableware. The raw material of our 100% Biodegradable Tableware is extracted from corn and other raw materials, and 100% of the renewable resources of PLA (Polyactic Acid polylactic acid) is extracted by science and technology. Without any plasticizing additives, it is pressed into environmentally safe tableware which is neither toxic nor degradable. It is long-term, high gloss and excellent heat resistance (-20℃ to 120℃). This Biodegradable Tableware is naturally degradable to water and carbon dioxide under photosynthesis and degradable environmental conditions. The traditional plastic products are petroleum-based raw materials. Once heated, they will produce toxicity. Besides the non-renewable resources, they cannot be naturally degraded.

PLA Disposable Tableware